Problem Possible Cause Fix
No Drip Rate Oil adjustment knob fully
clockwise
Readjust knob.
Low oil level Check oil level.
Airflow through lubricator too
low
Use smaller size lubricator.
Remove bowl and sight feed
adjustment dome and clear
syphon tube.
Blocked oil filter screen Remove sight feed adjustment
dome and clean or replace
screen located in dome
assembly.
Air leaks Check bowl, filler plug and
sight dome seals. Tighten if
necessary.
Oil Foaming Over aeration Check bowl seals for slight
leaks.
Oil Emulsified Water in lubricator Fit filter immediately upstream.
Drip Rate changes after setting Fade Readjust drip rate.